Daikin Perfera RXM R Series Service Manual page 196

Split r32
Table of Contents

Advertisement

3
|
Components
Service manual
196
▪ For outdoor unit air (ambient) thermistor:
Correctly install the thermistor in the holder and close the thermistor holder.
▪ For refrigerant piping thermistors:
Pull the clip and install the thermistor in the specific thermistor holder. Make
sure the clip is in the correct position (blocking the thermistor).
c
a
f
f
a Clip
b Thermistor
c Thermistor holder
d Insulation
e Thermistor wire
f Tie strap
6 Route the thermistor harness towards the appropriate PCB.
7 Connect the thermistor connector to the appropriate PCB.
INFORMATION
Some of the thermistors are wired to the same connector. See connector and pin
information of the thermistors at the start of the electrical check procedure and
"6.2 Wiring
diagram" [
to the same connector.
8 When installing the complete set of thermistors wired to the same connector:
b
e
d
4
 223]. ALWAYS replace the complete set of thermistors wired
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32