Indoor Unit Main Pcb; Checking Procedures - Daikin Perfera RXM R Series Service Manual

Split r32
Table of Contents

Advertisement

3
|
Components

3.9 Indoor unit main PCB

3.9.1 Checking procedures

To perform a power check of the indoor unit main PCB
Service manual
102
a
b
f
a Screw (upper air outlet assy)
b Upper air outlet assy
c Drain hose
d Damper motor wiring harness
e Screw (tie strap)
f Screw (lower air outlet assy)
g Lower air outlet assy
13 Route the damper motor wiring harness through the appropriate harness
retainers.
14 Install the screw to connect the tie strap to the unit.
15 Connect the drain hose to the lower air outlet assembly.
16 Install the drain hose fixation bracket. Install and tighten the screw.
17 Install the upper air outlet assembly in the correct location. Install and tighten
the 2 screws.
18 Install the switch box, see
19 Perform a pressure test on the piping of the indoor unit and vacuüm. Open
the stop valves when done.
Is the problem solved?
Yes
No
INFORMATION
It is recommended to perform the checks in the listed order.
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
a
g
c
f
4
"3.14 Plate
work" [
 151].
Action
No further actions required.
Return to
"Checking
procedures" [
fan motor and continue with the next
procedure.
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
d
e
4
 140] of the outdoor unit
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01