Daikin Perfera RXM R Series Service Manual page 74

Split r32
Table of Contents

Advertisement

3
|
Components
To remove the damper motor wiring harness
Service manual
74
a
b
a Screw (drain hose)
b Drain hose
c Screw (damper motor cover)
d Damper motor cover
e Screw (damper motor)
f Damper motor
g Damper motor wiring harness
3 Install the damper motor cover in the correct location on the indoor unit.
Make sure that the damper motor shaft is correctly inserted in the gear.
4 Install and tighten the 3 screw to fix damper motor covers.
5 Connect the drain hose to the indoor unit.
6 Install the drain hose fixation bracket. Install and tighten the screw.
Is the problem solved?
Yes
No
Prerequisite: Remove the damper motor, see
1 Remove the screw to disconnect the tie strap.
a
b
c
c
a Screw (tie strap)
b Damper motor wiring harness
c Harness retainer
d Damper motor connector on indoor unit main PCB
2 Route the damper motor wiring harness out of the harness retainers.
d
c
e
c
c
e
f
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
"Repair
c
c
d
c
b
c
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
g
4
procedures" [
 73].
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents