Repair Procedures - Daikin Perfera RXM R Series Service Manual

Split r32
Table of Contents

Advertisement

3
|
Components

3.9.2 Repair procedures

To remove the indoor unit main PCB
Service manual
106
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Disconnect all connectors from the indoor unit main PCB.
2 Carefully click the indoor unit main PCB out of the PCB retainers.
A
A Wall mounted indoor unit
a Indoor unit main PCB
A
A Floor standing indoor unit
a Indoor unit main PCB
"3.14 Plate
a
a
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
4
work" [
 151].
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01