(d) Set the parameter according to below recommendation, the max. charge current refer
to the specific battery amount of real application. Then click 'Apply'. According to the
inverter limitation, for 2kW&3kW inverter max. is 25A, for 5kW max. is 100A, for 10kW
max. is 200A.
2. WKS - Off-grid Solution
(1) General Compatible Condition:
Battery Type
Inverter Type
WKS 1K-48
Max.
33A
charge current
Recommend
According to load requirement and inverter rated power.
battery Amount
Battery Amount N = Load power/1200W
Communication
Not required, but need finish the setting on Inverter.
DOD
80%
Working Temp.
0 - 50℃(Indoor operation)
Charge/Dischar
N*25, N = Battery amount
ge Current
Warranty
5yrs
US2000B/Phantom-S
WKS 3K-48
WKS 4K
33A
140A
3
WKS 5K
140A