1 Hilti toolbox
2.11 Using extension cords
Use only extension cords of a type approved for the application and with conductors of adequate cross section.
The power tool may otherwise lose performance and the extension cord may overheat. Check the extension
en
cord for damage at regular intervals. Replace damaged extension cords.
Recommended minimum conductor cross section and max. cable lengths
Conductor cross section
Mains voltage 100 V
Mains voltage 110-127 V
Mains voltage 220-240 V
Do not use extension cords with 1.25 mm² conductor cross section.
2.12 Using extension cords outdoors
When working outdoors, use only extension cords that are approved and correspondingly marked for this
application.
2.13 Using a generator or transformer
This power tool may be powered by a generator or transformer when the following conditions are fulfilled:
The unit must provide a power output in watts of at least twice the value printed on the type identification
plate on the power tool. The operating voltage must remain within +5% and -15% of the rated voltage at all
times, frequency must be in the 50 – 60 Hz range and never above 65 Hz, and the unit must be equipped with
automatic voltage regulation and starting boost.
Never operate other power tools or appliances from the generator or transformer at the same time. Switching
other power tools or appliances on and off may cause undervoltage and / or overvoltage peaks, resulting in
damage to the power tool.

3. Insert tools, accessories, consumables

Designation
Hammer drill bits
Breach bits
Percussion core bits
PCM diamond core bits
Chisels
Wood drill bits
Metal drill bits
Designation
Side handle, complete
Depth gauge, complete
Anchor-setting tools
20
1.5 mm²
2.0 mm²
20 m
20 m
25 m
30 m
Short designation
TE 60 / TE 60‑ATC‑AVR
TE 60 / TE 60‑ATC‑AVR
TE 60 / TE 60‑ATC‑AVR
TE 60‑ATC‑AVR
TE 60 / TE 60‑ATC‑AVR
Short designation
TE 60 / TE 60‑ATC‑AVR
2.5 mm²
3.5 mm²
40 m
30 m
40 m
50 m
Description
Ø 12...40 mm
Ø 40...80 mm
Ø 45...100 mm
Ø 42...102 mm
Pointed, flat and shaped chisels
with TE‑Y connection end
Ø 10...32 mm
Ø Max. 20 mm
Item number, description
366482
Setting tools with TE‑Y connection
end