Electrical Connections - VERDER VERDERAIR VA-E50 Operation

Electric-operated diaphragm pump
Hide thumbs Also See for VERDERAIR VA-E50:
Table of Contents

Advertisement

Electrical Connections

Connections
Electrical
Electrical
Connections
Wire Connections
Connections at at at the
Wire
Wire
Connections
(Motor
(Motor
(Motor Code
Code 1, 1, 1, 2, 2, 2, C) C)
Code
C)
NOTE: Follow the instructions in the motor
NOTE:
NOTE:
manufacturer's manual. Use a motor starter with
overload protection. Wire size, fuse size, and other
electrical devices must comply with all local codes
and regulations.
The motor must be wired to the VFD. Install the
wiring at the motor as follows:
1. Open the motor's electrical box.
2. Install a strain relief in one of the ports at the
bottom of the junction box.
3. Connect the green ground wire to the ground
screw.
859.0761
the Motor
Motor
the
Motor
4. For
For 230
For
230 V V V motors:
230
motors: Bridge as shown, then
motors:
connect L1 to T1, L2 to T2, and L3 to T3.
T7
T1
L1
Figure 3 Wire Connections for a 230 V Motor
5. For
For 460
For
460 V V V motors:
460
motors: Bridge as shown, then
motors:
connect L1 to T1, L2 to T2, and L3 to T3.
T7
T1
L1
Figure 4 Wire Connections for a 460 V Motor
6. Close the motor electrical box. Torque the bolts
to 2.2 N•m (20 in-lb).
Installation
T8
T9
T2
T3
T8
T9
T2
T3
15