13.5.2 TOP VIEW
A (Roof)
B (To the sides)
C = D (Front and back)
52
14 STORAGE AND MAINTENANCE
The X2 Wave Flamers surfaces should be cleaned after every show. A normal cleaning cloth and
grain alcohol can be used to clean all outer components until no dirt is visible.
If soot settles on the ignition electrodes, they can be cleaned carefully using an old toothbrush. The
cables of the electrodes should be checked periodically for any obvious damages.
If stored for a longer duration (> 1 month) the Wave Flamer should be used for a moment, to lubricate
the inner system and prevent the pumps from drying out, as well as preventing parts from corroding.
Direction
The X2 Wave Flamer may never be stored will pressurized or
in armed mode. Due to safety reasons, we recommend
storage with 1L of fluid in the canister, which should prevent
an unwanted and harmful pressurizing of the pumps without
5m-nozzle
10m-nozzle
15 m (49,2 ft) *)
7 m (23 ft) *)
14 m (45,9 ft) *)
6 m (19,7 ft) *)
3,5 m (11,5 ft) *)
2,5 m (8,2 ft) *)
fluid.
Need help?