5.3.4
Flat keys jaw Setup
How to proceed:
• From the CALIBRATIONS MENU, select:
• Install the required jaw and select the corresponding code
from the JAW SETUP MENU (e.g. N01).
Note: Sample keys provided with the jaw must be used.
• Insert the blank in the reading jaw and lock it in place.
• Then press "3" to cut the key and, at the end, to measure
the actual key heights.
• If the measured heights are different from those shown on
the display, it is possible to correct them by changing the
position of the X-Y-RZ axes with the buttons:
• On the top left of the display it is possible to view the
height to be modified.
• Save your changes by pressing "1".
Note: If you leave the page without pressing the "1" key, all
changes shall be lost.
• This button (4) makes it possible to select and calibrate the
additional sides of the jaw, changing the key spacing and
depth using the keys
• To reset the changes and go back to the previous setting,
press "2".
Copyright by Keyline - Italy
SETUP
5.3.5
Adaptor Setup
How to proceed:
• From the CALIBRATIONS MENU, select:
• Install the preferred adapter, then choose the relevant
code from the ADAPTER SETUP MENU.
2
1
4
3
• Insert the blank in the adaptor and lock it in place.
• Then press "3" to cut the key and, at the end, to measure
the actual key heights.
• If the measured heights are different from those shown on
the display, it is possible to correct them by changing the
position of the X-Y axes with the buttons:
• On the top left of the display it is possible to view the
height to be modified.
• Save your changes by pressing "1".
Note: If you leave the page without pressing the "1" key, all
changes shall be lost.
• To reset the changes and go back to the previous setting,
press "2".
NINJA LASER
5.4.0
Update
It is possible to update the machine through the graphic interface.
How to access the page:
• From the SETUP MENU, select:
1
2
2
1
3
Options displayed:
1. To proceed with the online software and database up-
date, through the "Keyonline" service.
2. The update package is downloaded through a normal PC
connected to the internet and saved on a USB flash drive,
so as to be able to install it later on in the machine.
3. To proceed with the software and database update, tak-
ing the data from a USB flash drive.
• For further information select "
Man. cod. B409927FG
1 3
" from the display.
Keyline S.p.A.