Download Print this page

Global Error Routing; L3 External Input Flags - Texas Instruments OMAP36 Series Technical Reference Manual

Advertisement

L3 Interconnect
MPU SS
DSP SS
In addition to the SResp qualifier error reporting, some external targets use an SError signal to indicate
that an internal error has occurred. Some resetting action may be required before any new request can be
accepted, depending on the module and on the error itself. These signals are routed as flags internally to
the L3.
Table 9-28
interconnect, and aggregated to the L3 application error flag.
Target
Flag
GPMC
SError
SGX master
MError
SGX target
SError
2018
Interconnect
Public Version
Figure 9-8. Global Error Routing
Initiator agent
L3 interconnect flags
lists the possible errors reported through an SError, propagated externally to the L3
Table 9-28. L3 External Input Flags
Description
General-purpose error occurs in GPMC
module
General-purpose error occurs in SGX
master
General-purpose error occurs in SGX
target
Copyright © 2009–2010, Texas Instruments Incorporated
Initiator module
SResp=ERR
Target agent
TA ERROR_LOG
PM ERROR_LOG
From TA:
Protection violation,
TA request time-out,
target core error
Target module
Yes, in FLAG_STATUS register and in L3 TA
SERROR bit AGENT_STATUS[24]
Yes, in FLAG_STATUS register and in L3 IA
MERROR bit AGENT_STATUS[24]
Yes, in FLAG_STATUS register and in L3 TA
SERROR bit AGENT_STATUS[24]