Error Code Troubleshooting - Graco ProMix PD2K Repair Parts Manual

Electronic proportioner
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Troubleshooting

Error Code Troubleshooting

System errors alert you of a problem and help
prevent off-ratio spraying. There are three types:
Advisory, Deviation, and Alarm.
An Advisory records an event in the system, and will
clear itself after 60 seconds.
A Deviation records an error in the system but does
not shut down the equipment. The deviation must be
acknowledged by the user.
If an Alarm occurs, operation stops.
If any of the three types occur:
• Alarm buzzer sounds (unless in silent mode).
• Alarm popup screen shows the active alarm code.
• Status bar on the Advanced Display Module shows
the active alarm code.
• Alarm is saved in the date/time stamped log.
Code
Type
Description
B9A0
Advisory Volume
Rollover A
Current
B9AX
Advisory Volume
Rollover A
Lifetime
B9B0
Advisory Volume
Rollover B
Current
B9BX
Advisory Volume
Rollover B
Lifetime
B9D#
Advisory Volume
Rollover
Pump #
12
NOTE: When an error occurs be sure to determine
the code before resetting it. If you forget which code
occurred, the Errors screen displays the 200 most
recent errors, with date, time, and description.
NOTE: In some error codes listed below, a # symbol
is shown as the last digit. This symbol represents the
applicable pump number, which can vary. The unit's
display will show the applicable pump number as the
last digit in the code.
Problem
Batch counter for
material A rolled over.
Grand total counter for
material A rolled over.
Batch counter for
material B rolled over.
Grand total counter for
material B rolled over.
Grand total counter for
pump # rolled over.
Cause
The totalizer has
reached maximum
capable value and
started over at zero.
The totalizer has
reached maximum
capable value and
started over at zero.
The totalizer has
reached maximum
capable value and
started over at zero.
The totalizer has
reached maximum
capable value and
started over at zero.
The totalizer has
reached maximum
capable value and
started over at zero.
Solution
n/a
n/a
n/a
n/a
n/a
3A2800B

Advertisement

Table of Contents
loading