Graco ProMix PD2K Repair Parts Manual page 13

Electronic proportioner
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Code
Type
Description
B9S0
Advisory Volume
Rollover
Solvent
Current
B9SX
Advisory Volume
Rollover
Solvent
Lifetime
Alarm
CAC#
Comm.
Error Color
Change #
CA0X
Alarm
Comm.
Error ADM
CADX
Alarm
Comm.
Error Fluid
Module
CANX
Advisory Comm.
Error Booth
Control
CDC#
Alarm
Duplicate
Color
Change #
3A2800B
Problem
Batch counter for
material S rolled over.
Grand total counter for
material S rolled over.
System does not see
the Color Change
Module #.
System does not see
the Advanced Display
Module.
System does not
see the Enhanced
Fluid Control Module
(EFCM).
System does not see
the Booth Control (and
manual system).
System sees two or
more identical Color
Change Modules.
Cause
The totalizer has
reached maximum
capable value and
started over at zero.
The totalizer has
reached maximum
capable value and
started over at zero.
This communication
error indicates that
the network has lost
communication with
the Color Change
Module #.
This communication
error indicates that
the Network has lost
communication with
the Advanced Display
Module.
This communication
error indicates that
the Network has lost
communication with
the EFCM.
This communication
error indicates that
the Network has lost
communication with
the Booth Control
module.
More than one Color
Change Module is
connected in the
system with the same
address.
Troubleshooting
Solution
n/a
n/a
Check CAN cable
connections to
the Color Change
Module # and any
interconnected
modules.
Check CAN cable
connecting ADM to the
EFCM.
Check CAN cables
connecting ADM to
the EFCM. Replace
Cable or EFCM as
necessary.
Check CAN cables
connecting booth
control to the Isolation
board. Check Isolation
board power. Replace
cable, booth control,
Isolation board or
Barrier board as
necessary.
Check the system and
remove the extra color
change module.
13

Advertisement

Table of Contents
loading