11 Connection of the sensors

As regards consumption and dew point sensors, there is the possibility to provide the measured values as an
analog current signal 4 – 20 mA for further processing. In the connection diagrams, the collection of the
current signal for an external PLC/central control system or for an external display is explained.
SD21
Connecting plug
Connecting lead
4025252 (5 m)
SD23
Connecting plug
Connecting lead
4025253 (5 m)
SP21/SP61
Connecting plug
Connecting lead
4025252 (5 m)
SP22/SP62
Connecting plug
Connecting lead
Upon request
FS109/FS211/DP109
Connecting plug
Connecting lead
4014064 (5 m)
4014065 (10 m)
The following connection diagrams apply from XA.1 to XC.4!
SD/DP series = dew point sensors
FS series = consumption sensors
SP series = pressure transducer
METPOINT® BDL
Pin 1
Pin 2
+U
Not used
v
Brown
Pin 1
Pin 2
+U
Not used
v
Brown
Pin 1
Pin 2
+U
Not used
v
Brown
Pin 1
Pin 2
+U
GND
v
Brown
Black
Pin 1
Pin 2
SDI
- U
v
Brown
White
Connection of the sensors
Pin 3
+I
OUT
White
Pin 3
Pin 4
+I
Not used
OUT
White
Pin 3
+I
OUT
Blue
Pin 3
-U
v
Blue
Pin 3
+ U
+I (500 µA)
v
Blue
Pin 4
Pin 5
Not used
Not used
Pin 5
Pin 6
-U
GND
v
Blue
Black
Pin 4
Pin 5
Not used
Not used
Pin 4
Pin 5
-U
Not used
OUT
White
Pin 4
Pin 5
Not used
Black
Grey
21