5-7 Harmonic Function Measurement

1) Press " Harmonic Key " ( 3-25, Fig. 1 ) will enter
the Screen 1.
2) Press " V/A 1. 2. 3 Key " ( 3-27, Fig. 1 ) will enter
the Screen 2.
3) If the wave show the distortion, Press " V/A range Key "
( 3-28, Fig. 1 ), switch to VH or AH to let the waveform
not existing distortion as Screen 3, Screen 4.
4) Press " Left Key " ( 3-24, Fig. 1) or " Right Key " (
3-26, Fig. 1) will show the voltage or current Nth
harmonic value
Screen 1 ( 5-7 )