Product warranties may be found in the “Products” section on our Web site at www. bradleycorp.com. Special Note for Sprayhead/Bowl retrofit to retrofit new SS-3N sprayhead onto existing SS-3 bowl 2¼" (57mm) Drill hole Ø 1" (25mm) to 1½" (38mm). Existing Hole 1½" (38mm) Bradley • 215-1575 Rev. J; ECN 17-08-026 5/15/2018...
¼"-20 x ½" pan-head screws and washers. Do not tighten. Secure the bowl to the wall anchors with ³⁄₈" bolts and 1" min. O.D. washers, two places. Do not overtighten. Tighten the pan-head screws Do not overtighten. Bradley • 215-1575 Rev. J; ECN 17-08-026 5/15/2018...
Page 8
Loosen but do not remove the two mounting screws holding the valve bracket to the frame. Slide the valve bracket up and lift it from the frame. Attach the stop to the tempered wall stub-out. Bradley • 215-1575 Rev. J; ECN 17-08-026 5/15/2018...
Page 9
Reinstall the valve bracket. the sprayhead Connect the power supply cables into the proper from the power management valve’s circuit module into the gang valve circuit board. board plugs (any connection order will work properly). Bradley • 215-1575 Rev. J; ECN 17-08-026 5/15/2018...
Page 10
Pass your hand in front of each station’s sensor until all the air is purged from the lines and water is flowing smoothly. Reinstall the access panel. Bradley • 215-1575 Rev. J; ECN 17-08-026 5/15/2018...
Page 11
. If there is inadequate lighting available in the location where the unit is installed, add additional lighting . If additional lighting is unavailable, the system may be converted to battery power . Contact Bradley and order Battery Pack Kit S45-2083 (one per station) . Improper Test for proper water pressure .
198-014 Check Valve* 132-051 Retaining Ring* 118-319 Valve Body 146-079 U-Clip * Included with Prepack S65-326 Tempered Line Adapter Option Part no. S39-804 (replaces S59-4000 if tempered line is used) Strainer (173-028) Bradley • 215-1575 Rev. J; ECN 17-08-026 5/15/2018...
Avoid contact with hot pans and objects. Repair Kits: Terreon repair kits are available . Contact your Bradley representative or distributor for part numbers and pricing . Repair kits are made to order and have a shelf life of 30 days .
To change soap, pour out all of the soap from the dispenser ans rinse with hot water several times until all residue is removed. Pump the valve until clean water appears. Rinse the dispenser with ethyl alcohol; air dry before refilling. Bradley • 215-1575 Rev. J; ECN 17-08-026 5/15/2018...