CAM PULLEY/CRANKSHAFT/ PISTON/CYLINDER
HRX217HYA • HRX217HZA
CRANKCASE COVER MAIN JOURNAL I.D.
Measure the crankcase cover main journal I.D.
STANDARD:
25.420 – 25.441 mm (1.0008 – 1.0016 in)
SERVICE LIMIT:
25.466 mm (1.0026 in)
If the measurement is more than the service limit, replace the
crankcase cover.
CRANKCASE MAIN JOURNAL I.D.
Measure the crankcase main journal I.D.
STANDARD:
28.020 – 28.041 mm (1.1031 – 1.1040 in)
SERVICE LIMIT:
28.066 mm (1.1050 in)
If the measurement is more than the service limit, replace the
crankcase.
CRANKSHAFT AXIAL CLEARANCE
Measure the crankshaft axial play before removing the oil pan,
crankshaft, and piston.
STANDARD:
0.15 – 0.65 mm (0.006 – 0.026 in)
SERVICE LIMIT:
1.0 mm (0.04 in)
If the measurement is more than the service limit, inspect the thrust
washer, timing gear, crankshaft, crankcase, and crankcase cover
for wear or damage.
10-20