5.5 Turning On of the Fan Running/Alarm Indicator

This section describes how to handle the fault when the fan running/alarm indicator is on.
Symptom
The fan running/alarm indicator on the fan module in the storage system is on.
Possible Causes
One of the following causes may arouse the turning on of the fan running/alarm indicator:
l
l
5-10
Cause 1: The disk is badly connected to the backplane.
1.
Remove and insert the disk again.
WARNING
To prevent damaging the disk or the connector, carefully remove the disk or install
l
the disk with equal force.
Before inserting the disk, release the handle of the disk to the maximum angle;
l
otherwise, the disk cannot be fully inserted into the empty slot.
2.
If the disk alarm/location indicator is off minutes after you insert the disk again, you
can determine that the fault is caused by bad connection between the disk and the
backplane.
Cause 2: The disk is faulty.
1.
Remove and insert the disk again.
2.
If the disk alarm/location indicator is on after you insert the disk again, you can
determine that the disk is faulty.
Cause 1: The disk is badly connected to the backplane.
1.
Remove and insert the disk again.
2.
After the disk is inserted again, the disk alarm/location indicator is off minutes later.
The fault is handled.
Cause 2: The disk is faulty.
1.
Replace the faulty disk by a new one.
2.
After the disk is inserted again, the disk alarm/location indicator is off minutes later.
The fault is handled.
The fan module is badly connected to the backplane.
The fan module is faulty.