Huawei OceanStor S2600 Manual page 30

Hide thumbs Also See for OceanStor S2600:
Table of Contents

Advertisement

3 Troubleshooting Process
Module
Power
module
Controller
3-4
Type of indicators Color
Power running/
alarm indicator
Active indicator of
the management
network port
Link indicator of the
management
network port
Controller power
indicator
Controller alarm
indicator
Link indicator of the
mini SAS expander
port
Link indicator of the
FC host port
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Status
Red
On
-
Off
Green
On
Orange
Blinking
-
Off
Orange
Blinking
-
Off
Green
On
-
Off
Green
On
-
Off
Red
On
Red
On, and
off after
five
seconds;
on and
then off
after the
controller
starts
normally
-
Off
Green
On
-
Off
Green
On
OceanStor S2600 Storage System
Troubleshooting
Description
An alarm is generated on the
fan.
The fan module is powered on
abnormally.
The power supply is normal.
An alarm is generated on the
power supply.
The controller enclosure is not
powered on or the power
module is powered on
abnormally.
Data is being transmitted.
No data is transmitted.
The link of the management
network port is normal.
The link of the management
network port is abnormal.
The controller is powered on
normally.
The controller is powered on
abnormally.
An alarm is generated on the
system.
The controller is starting.
The system is normal.
The disk channel is normal.
The disk channel is abnormal.
The connection between the
storage system and the AS is
normal.
Issue 03 (2010-01-28)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V100r002

Table of Contents