Analog way HD SCAN XTD920 User Manual page 22

Table of Contents

Advertisement

Available languages

Available languages

Chapter 11 : RS-232 PROGRAMMER'S GUIDE (continued)
11-4. COMMANDS AND RESPONSES TABLE (continued)
ASCII
RESPONSE
COMMAND
STATUS COMMANDS
U
UNIT
il
ILD
id
IFD
ik
IST
ip
IPS
ih
IHP
iv
IVP
ii
IIN
io
IOO
if
IFA
GA
REFA
GF
REFF
GT
REFT
NOTE: Rd = Read only command.
PAGE 22
COMMAND
DESCRIPTION
Measures unity in kHz.
This command allows to calculate the
input line frequency in kHz
This command allows to calculate the
input frame frequency in Hz.
Input sync type detection
Input sync detection.
Sign of the horizontal input sync.
Sign of the vertical input sync.
Interlaced signal detection.
Status of the signal in comparison with
the input range frequency.
Input format detection
Status of the synchronization mode
Status of the synchronized format
(genlock).
Frame frequency of the synchronized
signal (genlock) (in hundredth of Hz)
TYPE
MIN MAX
Rd
0
65535
Rd
0
65535 Line frequency (in kHz) = (UNIT VALUE) ÷
Rd
0
65535 Frame frequency (in Hz) = (Line frequency in
Rd
0
3
Rd
0
1
Rd
0
1
Rd
0
1
Rd
0
1
Rd
0
1
Rd
0
1
Rd
0
3
Rd
0
9
Rd
0
65535
Rd/Wr = Read and write command.
VALUE
DESCRIPTION
(ILD VALUE).
Hz) ÷ (IFD VALUE).
0 = separate H & V
1 = Composite sync (TTL)
2 = SOG (Sync On Green)
3 = Composite sync (analog)
0 = no sync detected
1 = sync detected
0 = negative
1 = positive
0 = negative
1 = positive
0 = not interlaced
1 = interlaced
0 = in range
1 = out of range
0 = no signal
1 = "out of range" signal.
2 = VGA1 350l
3 = VGA2 400l
4 = VGA3 480l
5 = SVGA
6 = XGA
7 = SXGA
8 = UXGA.
0 = internal
1 = genlock
0 = no signal
5 = 1035i @ 59.94Hz
1 = "out of range" signal 6 = 1035i @ 60Hz
2 = 720p @ 50Hz
7 = 1080i @ 50Hz
3 = 720p @ 59.94Hz
8 = 1080i @ 59.94Hz
4 = 720p @ 60Hz
9 = 1080i @ 60Hz.