If The Display Reads Spid{1,3,5, Or 7; If The Display Reads Spid{2,4,6, Or 8 - ADTRAN ISU 512 User Manual

Adtran isdn service unit user manual isu 512
Hide thumbs Also See for ISU 512:
Table of Contents

Advertisement

IF THE DISPLAY READS SPID{1,3,5, OR 7}

This section does not apply to installations outside of North America.
If the ISU 512 reads SPID1, then the ISU 512 is physically connected to the lo-
cal telephone service provider and has established Logical Layer 2. The ISU
512 is unable to establish layer 3. The problem is with one or more of the fol-
lowing:
The ISU 512 software setup
The software setup of the telephone service provider
To isolate the problem, use the following procedure:
1.
Ensure the ISU 512 is set up for the correct switch type by selecting CON-
FIG, Netw. options, Dial Line, and Switch type.
2.
Ensure that the ISU 512 is set up with the correct SPID and LDN by select-
ing CONFIG, Netw. options, Dial Line, Terminal ID, and SPID/LDN.
Review the section Setting the SPID in the chapter Configuration.
3.
Connect another piece of functioning ISDN equipment to the ISDN line.
4.
With the ISU 512 connected to the ISDN line and powered up, talk to your
service provider's repair group and inform them you have an ISDN basic
rate line that appears physically OK but has no Terminal Endpoint Identi-
fier (TEI). Ask them to check the ISDN line translation and ensure that the
line supports dynamic TEI allocation. Inform them an NT1 and terminal
adapter device are connected to the ISDN line.

IF THE DISPLAY READS SPID{2,4,6, OR 8}

This section does not apply to installations outside of North America.
If the ISU 512 continues to read SPID2, the ISU 512 has completely initialized
the first phone number but is unable to establish Logical Layer 3 for the second
phone number. The problem is with one or more of the following:
61202.086L1-1
Chapter 7: Troubleshooting
ISU 512 User Manual
65

Advertisement

Table of Contents
loading

Table of Contents