Appenidix B. S-Register List
S34 . . . .DTE DTR. . . . . . . . . . . . . Determines how the ISU 512 responds to changes in DTR.
S35 . . . .DTE CONN . . . . . . . . . . . Determines which is the current operating DTE connector.
S40 . . . .BOND TXINIT . . . . . . . . Specifies the number of seconds the originating end point
S41 . . . .BOND TXFA. . . . . . . . . . Specifies the number of seconds both end points attempt to
S42 . . . .BOND TXADD01 . . . . . . The number of seconds both end points wait for the addi-
S43 . . . .BOND TXDEQ . . . . . . . . The number of seconds both end points attempt to equalize
S44 . . . .BOND TANULL . . . . . . . The number of seconds the answering end point attempts to
80
0=Ignore DTR (default)
2=Dump incoming call when DTR is off
4=Hang-up incoming call when DTR is off
8=Hang-up outgoing call when DTR is off
0=V.35 connector (default)
1=RS-530 connector
attempts to detect the BONDING negotiation pattern from
the answering end point before deciding the BONDING
call has failed. 0 to 256, 10 sec is default.
detect the BONDING frame pattern when a call is connect-
ed before deciding the BONDING call has failed. When
operating with other manufacturer's BONDING equipment
it may be necessary to lengthen this timer so that it matches
TXADD01. 0 to 256, 10 sec is default.
tional call to be connected at the end of negotiation before
deciding the BONDING call has failed. When dialing over-
seas, it may be necessary to lengthen this timer to allow for
lower call routing. 0 to 256, 50 sec is default.
the network delay between the bearer channels before de-
ciding the BONDING call has failed. 0 to 256, 5 sec is de-
fault.
detect the BONDING negotiation pattern from the origi-
nating end point before aborting to clear channel mode. It
may be necessary to shorten this timer if the DTE equip-
ment connected to the ISU 512 also has timer constraints
for completing non-BONDING parameter negotiation. 0
to 256, 10 sec is default.