IF SELF TEST FAILS

When the ISU 512 powers up, it performs an internal self test. This takes ap-
proximately 10 seconds. At the end of the test, the front panel displays Self
Test Passed. If Self Test Passed is not displayed, perform the following pro-
cedure to verify if the problem can be solved locally:
1.
Ensure the ISU 512 is receiving power and is switched On.
2.
Turn Off the ISU 512; while holding the 0 key, power up the ISU 512. Con-
tinue holding 0 for approximately 30 seconds, until the unit powers up.
This resets all the internal settings to factory defaults and erases SPID and
LDN information.
3.
If the ISU 512 still does not pass Self Test, call ADTRAN Technical Sup-
port; see the inside back cover of this manual.

IF AN ISDN NETWORK LINE READS DOWN

If EuroISDN switch type is selected and the front panel displays DOWN, it is only an
indication that a call has not been placed to activate the line.
When the ISU 512 has been set up, connected to ISDN lines, and the front panel
displays DOWN for any of the network ISDN lines, use the following trouble-
shooting procedure:
1.
Cycle power on the ISU 512, leaving it Off for a minimum of 2 seconds.
2.
If Ready is not displayed after waiting another full minute, disconnect the
ISU 512 from the ISDN line. Using a functioning voice phone, call the local
61202.086L1-1
Troubleshooting
ISU 512 User Manual
Chapter 7
61