Item
Condition
Panel tuning
mode
4.
1)Adj item:
Ramp
[RAMP]
Offset
Adjust:[****]
PTT : ON
Press [
]
button to store
the adjustment
value.
5.
1) Adj item:
Balance
[An BAL]
Adjust:[****]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[L1]→
[L3]→
[C2]→
[H1]→
[H3]
Adjust:[****]
PTT : ON
Press [
]
button to store
the adjustment
value.
Measurement
PC test mode
Test-
equipment
1) Adj item:
Power
[Ramp Offset]
meter
Press
Ammeter
[Autotune(TX
starts)] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item:
Deviation
[Balance]
meter
Deviation meter
Oscilloscope
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Unit Terminal Unit
Parts
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[+], [-]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[+], [-]
Adjustment
Specifications
Method
[PC test mode]
[Automatic
Adjustment]
1) Press [Autotune(TX
starts)] button.
2) Press [Apply] button
to store the
adjustment value
after the automatic
adjustment has
finished.
3) Check Ramp Offset
Monitor Value Over
60.
[Manual Adjustment]
1) Set the adjustment
value to "1".
2) Press [Transmit]
button and increase
the adjustment value
slowly while
monitoring the offset
monitor value.
3) Set the adjustment
value when the
offset monitor value
exceed "75".
The Deviation of 20Hz
2kHz Tone
frequency is fixed.
deviation is
Change the 2kHz
within ± 1.0%
adjustment value to
of 20Hz tone
become the same
deviation.
deviation of 20Hz
within the specified
range.
[Panel tuning mode]
PTT:ON
While PTT:ON, press
the [] button to
change the 20Hz/
2kHz.
[PC test mode]
PTT: Press [Transmit]
button.
While PTT:ON, click
the check box "2kHz
Sine Wave" to change
the 20Hz/2kHz.
(No.RA054<Rev.001>)1-73