Item
Condition
Panel tuning
mode
[DMR]
1) Adj item:
[D SQL]
Adjust:[****]
2) Adj item:
[L1]→
[L3]→
[C2]→
[H1]→
[H3]
SSG output:
12dB SINAD
level at Analog
Narrow
-4dB
(MOD: 400Hz/
±1.8kHz)
5.
1) Adj item:
Squelch
[Aw SQLT]
Tight
Adjust:[****]
2) Adj item:
[Analog
[L1]→
Wide]
[L3]→
[C2]→
[H1]→
[H3]
SSG output:
12dB SINAD
level +6dB
(MOD: 1kHz/
±3kHz)
[Analog
1) Adj item:
Narrow]
[An SQLT]
Adjust:[****]
2) Adj item:
[L1]→
[L3]→
[C2]→
[H1]→
[H3]
SSG output:
12dB SINAD
level +6dB
(MOD: 1kHz/
±1.5kHz)
1-58 (No.RA054<Rev.001>)
PC test mode
Test-
equipment
1) Adj item:
SSG
[Squelch Open
Distortion
(DMR)]
meter
2) Adj item:
Oscilloscope
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output: 12dB
SINAD level at
Analog Narrow
-4dB
(MOD: 400Hz/
±1.8kHz)
1) Adj item:
SSG
[Squelch Tight
Distortion
(Analog Wide)]
meter
2) Adj item:
Oscilloscope
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level
+6dB
(MOD: 1kHz/
±3kHz)
1) Adj item:
SSG
[Squelch Tight
Distortion
(Analog Narrow)]
meter
2) Adj item:
Oscilloscope
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level
+6dB
(MOD: 1kHz/
±1.5kHz)
Measurement
Unit Terminal Unit
Panel ANT
Panel
Ext. SP
connector
Panel ANT
Panel
Ext. SP
connector
Panel ANT
Panel
Ext. SP
connector
Adjustment
Parts
Method
[Panel tuning mode]
After input signal from
SSG, press [
]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
[Panel tuning mode]
After input signal from
SSG, press [
]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
[Panel tuning mode]
After input signal from
SSG, press [
]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
Specifica
tions
/Remarks

Hide quick links:

Advertisement

loading