Kenwood NX-3720HG Service Manual page 106

Vhf digital transceiver, uhf digital transceiver
Hide thumbs Also See for NX-3720HG:

Advertisement

Item
Condition
Panel tuning
mode
9.
1) Adj item:
DMR High
[D DDEV]
Deviation
Adjust: [****]
2) Adj item:
[L1]→
[L3]→
[L5]→
[C1]→
[C3]→
[C5]→
[H2]→
[H4]→
[H6]
Adjust:[****]
PTT : ON
Press [
]
button to store
the adjustment
value.
10. QT
1) Adj item:
Deviation
[Aw QT]
Adjust:[****]
[Analog
2) Adj item:
Wide]
[L1]→
[L3]→
[L5]→
[C1]→
[C3]→
[C5]→
[H2]→
[H4]→
[H6]
Adjust:[****]
PTT : ON
Press [
]
button to store
the adjustment
value.
1-106 (No.RA054<Rev.001>)
Measurement
PC test mode
Test-
equipment
1) Adj item:
Deviation
[DMR High
meter
Deviation (DMR
Oscilloscope
Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
1) Adj item:
Deviation
[QT Deviation
meter
(Analog Wide)]
Oscilloscope
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Unit Terminal Unit
Parts
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[+], [-]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[+], [-]
Adjustment
Specifications
Method
Write fixed value for
2695~2803Hz
each adjustment point.
(The value is written
below.) Transmit at
each adjustment point
and check that the
Analog deviation is
between 2695Hz and
2803Hz.
Deviation meter
LPF: 3kHz
HPF: OFF
K:503(Reference
value)
K2:496(Reference
value)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
Write the value as
0.75kHz±0.05
followings.
kHz
K:520(Reference
value)
K2:529(Reference
value)
/Remarks