Item
Condition
Panel tuning
mode
13. Single
1) Adj item:
Tone
[Aw TONE]
Deviation
Adjust:[****]
2) Adj item:
[Analog
[L1]→
Wide 5k]
[L3]→
[L5]→
[C1]→
[C3]→
[C5]→
[H2]→
[H4]→
[H6]
Adjust:[****]
PTT : ON
Press [
]
button to store
the adjustment
value.
[Analog
1) Adj item:
Wide 4k]
[As TONE]
Adjust:[****]
2) Adj item:
[L1]→
[L3]→
[L5]→
[C1]→
[C3]→
[C5]→
[H2]→
[H4]→
[H6]
Adjust:[****]
PTT : ON
Press [
]
button to store
the adjustment
value.
1-142 (No.RA054<Rev.001>)
Measurement
PC test mode
Test-
equipment
1) Adj item:
Deviation
[Single Tone
meter
Deviation (Analog
Oscilloscope
Wide 5k)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
1) Adj item:
Deviation
[Single Tone
meter
Deviation (Analog
Oscilloscope
Wide 4k)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Unit Terminal Unit
Parts
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[+], [-]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[+], [-]
Adjustment
Specifications
Method
Write the value as
3.00kHz±0.05
followings.
kHz
511(Reference value)
Write the value as
2.40kHz±0.05
followings.
kHz
511(Reference value)
/Remarks