Item
Panel test
mode
3.
1)CH-Sig: 1-1
Low
PTT: ON
power
TA: OFF
check
2)CH-Sig: 2-1
PTT: ON
TA: OFF
3)CH-Sig: 3-1
PTT: ON
TA: OFF
4.
1)CH-Sig: 1-1
MIC
AG: 1kHz
sensitivity
PTT: ON
check
5.
1)CH-Sig: 1-1
Sensitivity
SSG output
check
Wide 5k:
-117dBm
(0.32μV)
(MOD:
1kHz/±3kHz)
Wide 4k:
-117dBm
(0.32μV)
(MOD: 1kHz/
±2.4kHz)
Narrow:
-117dBm
(0.32μV)
(MOD: 1kHz/
±1.5kHz)
Condition
PC test mode
1)Test Channel
Power meter
Channel: 1
Ammeter
Test Signaling
Type: Analog
Signaling: 1
PTT: Press
[Transmit] button.
2)Test Channel
Channel: 2
Test Signaling
Type: Analog
Signaling: 1
PTT: Press
[Transmit] button.
3)Test Channel
Channel: 3
Test Signaling
Type: Analog
Signaling: 1
PTT: Press
[Transmit] button.
1)Test Channel
Deviation
Channel: 1
meter
Test Signaling
Oscilloscope
Type: Analog
AG
Signaling: 1
AF VM
AG: 1kHz
PTT: Press
[Transmit] button.
1)Test Channel
SSG
Channel: 1
AF VM
Test Signaling
Oscilloscope
Type: Analog
Distortion
Signaling: 1
meter
SSG output
4ohm
Wide 5k:
Dummy load
-117dBm (0.32μV)
(MOD: 1kHz/±3kHz)
Wide 4k:
-117dBm (0.32μV)
(MOD: 1kHz/±2.4kHz)
Narrow:
-117dBm (0.32μV)
(MOD: 1kHz/±1.5kHz)
Measurement
Test-
Unit
Terminal Unit Parts
equipment
Panel ANT
Panel ANT
MIC jack
Panel ANT
Ext. SP
connector
Adjustment
Specifications
/Remarks
Method
Check
3.5W~6.5W
7.0A or less
Adjust
AG
5mV ±1mV
input to get a
standard
MOD.
Check
12dB SINAD
or more
(No.RA054<Rev.001>)1-69

Hide quick links:

Advertisement

loading