4.35.1 Necessary Deviation adjustment item for each signaling and mode
The following shows the necessary adjustment items for each signaling deviation. Please read the following table like the following
example. In the case of the signaling "QT (Analog Wide 5k)", this signaling is composed of three elements [Balance, Maximum
Deviation (Analog Wide 5k) and QT Deviation (Analog Wide 5k)]. Please adjust Balance and Maximum Deviation (Analog Wide 5k)
before adjusting QT Deviation (Analog Wide 5k).
Mode Signaling
Analog Audio
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
QT
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. QT Deviation
[Analog Wide 5k]
DQT
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. DQT Deviation
[Analog Wide 5k]
LTR
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. LTR Deviation
[Analog Wide 5k]
DTMF
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. DTMF Deviation
[Analog Wide 5k]
5TONE
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. Single Tone Deviation
[Analog Wide 5k]
MSK
1. Balance adjust
(Fleet
2. Maximum Deviation
sync)
[Analog Wide 5k]
3. MSK Deviation
[Analog Wide 5k]
NXDN Audio
CWID
DMR
Audio
• Balance is common with all the above deviation adjustments. If Balance (Transmitter Section 6) has already adjusted, please skip
Step1 and adjust from Step2.
• Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) is common with all the analog signaling deviations and CWID Deviation
(NXDN Very Narrow).
If Balance and Maximum Deviation (Analog Wide 5k/Wide 4k /Narrow) (Transmitter Section 7) have already adjusted, please skip
Step2 and adjust from Step3.
1-146 (No.RA054<Rev.001>)
Wide 5k
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. QT Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. DQT Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. LTR Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. DTMF Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. Single Tone Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. MSK Deviation
[Analog Wide 4k]
-
-
-
Necessary adjustment and order
Wide 4k
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. QT Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. DQT Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. LTR Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. DTMF Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. Single Tone Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. MSK Deviation
[Analog Narrow]
-
1. Balance adjust
2. NXDN High Deviation
[NXDN Narrow]
-
-
1. Balance adjust
2. DMR High Deviation
Narrow
Very Narrow
1. Balance adjust
2. NXDN High
Deviation
[NXDN Very Narrow]
-
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. CWID Deviation
[Analog Narrow]
-
-
-
-
-
-
-
-