MFG SETUP SCREEN
These settings are preset and are based on the START-
UP WIZARD SCREEN (page 24). Change only if need-
ed!
Step 1:
Touch the WHEEL VOLUME button icon. The
button will display a value: navigates to a pop-up touch
pad (not shown).
For the RH 2000 enter a 1.0580 val-
ue, for the RH 800 enter a .4950 value. Then touch the
OK button icon: pop-up window closes.
Step 2:
Touch the Kg/Min button icon. Select either Kg/
Min or LBS/MIN. The button value will toggle between
the two types of unit of measure. Select one.
Step 3:
Touch the SEED WHEEL MAX FLOW SP button
icon: navigates to a pop-up touch pad (not shown). For
the RH2000 enter a 2100 value for LBS/MIN or a 2500
value for Kg/Min. For the RH800 enter a 900 value for
LBS/MIN or a 1100 value for Kg/Min.
Then touch the OK button icon. The value will display*
on the SEED WHEEL MAX FLOW SP button: the pop-
up window closes. *Display of Kg/Min or LBS/MIN
value may not update until user exits/re-enters the MFG
SETUP SCREEN.
Step 4:
Touch the # PUMPS button icon. Select either 2
PUMP or 4 PUMP option. The button will toggle be-
tween 2 or 4 pumping systems. Select one.
Step 5:
Touch the DIAG. button icon: navigates to the
DIAGNOSTICS SCREEN 
# Pumps
4
Seed Units
Kg/Min
English
Tune
Seed Wheel
Auto Tune
Pump 1
Auto Tune
Pump 2
Auto Tune
Pump 3
Auto Tune
Pump 4
Auto Tune
Exit
Calibrate
Main
Manual
Pump
52
Setup MFG
Seed Wheel Max Flow SP
1000.0
Kg/Min
Support Info
Batch Data
Alarms
Seed Wheel
Calibration Parameters
Motor RPM @ 60 Hz
1783
Gear Box Ratio
40
Wheel Volume (cu. ft.)
0.4950
Weigh Container Vol. (cu. ft.)
0.0508
Diag.
1/19/2018
Setup
1:32 PM