CONFIGURATION
Initiate Seed Coater Program
Step 1:
Turn ON the Main Power Switch (handle in DOWN
position as shown right).
Step 2:
Ensure the E-STOP button is pulled OUT
(deactivated). See note below.
Step 3:
Turn ON the Control Power Switch Right, as shown.
The HMI will initiate the program (boot up): navigates
to display the STARTUP WIZARD SCREEN 
Emergency Stop Button
To release and deactivate the E-STOP button, twist
the E-STOP button clockwise : the E-STOP button
will pop out. Release is necessary when starting up the
HMI...IT WILL NOT START IF THE CONTROL PANEL
E-STOP BUTTON IS PUSHED IN (ACTIVATED).