Manufacturer's Information; Transport; Delivery And Performance; Storage - GEM 601 Installation, Operating And Maintenance Instrutions

Diaphragm valve
Table of Contents

Advertisement

Available languages

Available languages

Special function
3-A compliant design
Order example
Type
Nominal size
Body configuration (code)
Connection (code)
Valve body material (code)
Diaphragm material (code)
Control function (code)
Bonnet version (code)
Surface finish (code)
Special function (code)
7

Manufacturer's information

7.1

Transport

Only transport the valve by suitable
G
means. Do not drop. Handle carefully.
Dispose of packing material according
G
to relevant local or national disposal
regulations / environmental protection
laws.
7.2

Delivery and performance

Check that all parts are present and
G
check for any damage immediately upon
receipt.
The scope of delivery is apparent from
G
the dispatch documents and the design
from the order number.
The performance of the valve is checked
G
at the factory.
7.3

Storage

Store the valve free from dust and
G
moisture in its original packaging.
Store the valve in "open" position.
G
Avoid UV rays and direct sunlight.
G
Maximum storage temperature: 40 °C.
G
Solvents, chemicals, acids, fuels or
G
similar fluids must not be stored in the
same room as valves and their spare
parts.
601, 602
601
8
D
601
8
D
22/32
60
C3
54
60
C3
54
7.4

Tools required

The tools required for installation and
G
assembly are not included in the scope
of delivery.
Use appropriate, functional and safe
G
tools.
8

Functional description

GEMÜ 601 / 602 is a metal diaphragm valve
with a 2/2-way, T or tank bottom valve body
or in multi-port design. Bonnet and internals
are made all of stainless steel. GEMÜ
601 has a temperature resistant plastic
handwheel, GEMÜ 602 has a stainless
steel handwheel. An integral optical position
indicator and a seal adjuster are included as
standard. The valve body and the diaphragm
are available in various designs as shown in
the data sheet.
The valve has CIP / SIP cleaning and
sterilizing capabilities and autoclave
capability.
Code
0
0TS
1500
0
0TS
1500
M
M
M

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

602

Table of Contents