Teledyne Linea HS Series User Manual page 100

Monochrome, color and multifield tdi line scan
Table of Contents

Advertisement

Display Name
Rotary Encoder Direction
Counter Clockwise
Clockwise
Rotary Encoder Output
Mode
Position
Motion
Input Line Debouncing
Period
Rotary Encoder Multiplier
Rotary Encoder Divisor
Rotary Encoder Rescaler
Order
Multiplier Divider
Divider Multiplier
Trigger Delay
Line Selector
Line 1
Line 2
Line 3
Line 4
Line 5
Line 6
Output Line Source
Off
On
Output Line Pulse Delay
Pulse Duration
Line Inverter
Off
On
100 • Appendix A: GenICam Commands
Feature
rotaryEncoderDirection
CounterClockwise
Clockwise
rotaryEncoderOutputMode
Position
Motion
lineDebouncingPeriod
rotaryEncoderMultiplier
rotaryEncoderDivider
rotaryEncoderRescalerOrder
multiplierDivider
dividerMultiplier
TriggerDelay
LineSelector
GPIO1
GPIO2
GPIO3
GPIO4
GPIO5
GPIO6
outputLineSource
Off
On
outputLinePulseDelay
outputLinePulseDuration
LineInverter
Off
On
Description
Specifies the phase which defines the encoder
forward direction.
Inspection goes forward when the rotary encoder
direction is counter clockwise (phase A is ahead of
phase B).
Inspection goes forward when the rotary encoder
direction is clockwise (phase B is ahead of phase A).
Specifies the conditions for the Rotary Encoder
interface to generate a valid Encoder output signal.
Triggers are generated at all new position
increments in the selected direction. If the encoder
reverses no trigger events are generated until it has
again passed the position where the reversal started.
The triggers are generated for all motion increments
in either direction.
Specifies the minimum delay before an input line
voltage transition is recognizing as a signal
transition.
Specifies a multiplication factor for the rotary
encoder output pulse generator.
Specifies a division factor for the rotary encoder
output pulse generator.
Specifies the order that the multiplier and divider are
applied.
The signal is multiplied before been divided.
The signal is divided before been multiplied
Allows the trigger to the sensor to be delayed
relative to camera input trigger
Selects the physical line (or pin) of the external
device connector to configure.
Index of the physical line and associated I/O control
block to use.
Selects which features control the output on the
selected line.
Line output level is controlled by the
outputLineSoftwareCmd feature.
Line output level is controlled by
outputLinePulseDelay, outputLinePulseDuration, and
LineInverter features.
Sets the delay (in µs) before the output line pulse
signal. Enabled by the OutputLineSource feature.
Sets the width (duration) of the output line pulse in
microseconds.
Controls whether to invert the polarity of the
selected input or output line signal.
The line signal is not inverted.
The line signal is inverted.
Linea HS Series Camera User's Manual
View
Beginner
DFNC
Beginner
DFNC
Beginner
DFNC
Beginner
Beginner
DFNC
Beginner
DFNC
Beginner
Beginner
Beginner
DFNC
Beginner
DFNC
Beginner
DFNC
Beginner