ULTRASONIC VOLUMETRIC PROTECTION

11.1 - C

ONNECTION AND POSITIONING

Insert the WHITE connector into the port marked "W" and the RED connector into the port marked
"R"(see figure below).
Install the sensor transducers at the top of each windscreen pillar, away from the air vents and orient
them towards the center of the rear window

11.2 - SENSOR ADJUSTMENT

T
o check sensitivity level proceed as follows
!
With the alarm system disarmed, roll down the front window about 20 cm.
!
Adjust trimmer at a medium setting.
!
Close all doors, bonnet and boot and arm the system.
!
During the system inhibit arming time introduce an object in the cabin through the window and
move it around; the status LED will turn off to indicate object detection.
!
If sensitivity is too high or too low, readjust the trimmer and repeat the above procedure.
SENSIBILITY
ADJUSTMENT
12.0 - WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
(WEEE) DIRECTIVE
In the European Union, this lable indicated that this product should not be disposed of with household
waste. It should be deposited at an appropriate facility to enable recovery and recycling (directive
2002/95/CE, 2002/96/CE and 2003/108/CE).
For information on how to recycle this product responsibly in your Country, please visit the web-site:
Www.eur-lex.europa.eu
PAGE 12 - INSTALLER MANUAL
.
:
CONNECTIONS
!
APPROPRIATE
CONTAINER ONLY

13.0 - TAG CARD ACTIVATION AND BATTERY REPLACEMENT

To activate the TAG CARD simply press the button and keep it pressed for at least 4 seconds.
The LED turns on steady when the TAG is activated and it will flash each time the TAG transmits.
If not moved for 10 min., the TAG will automatically go into standby to save battery life; to' wake it up' for
another transmission cycle (10 min.), move it or press the button
Another short button press will send a radio signal to the alarm system.
To turn the TAG off, press the button and keep it pressed for at least 8 seconds.
The LED stays on steady and after 8 seconds it will flash briefly to indicate the TAG is switched off.
To replace battery proceed as follows:
Separate the plastic
covers and remove the
circuit with care.
ULTRASONIC
CELLS
Use ONLY CR2032 type battery; do not discard used batteries in trash but safely
Figure 1
Reassemble the covers, turn
on the TAG and make sure it
Figure 3
dispose in appropriate containers.
.
Slide out dead battery
and insert new one.
Pay attention not to
invert polarity.
+
Figure 2
works.
INSTALLER MANUAL - PAGE 13