Extreme Networks ExtremeSwitching Virtual Services Platform 8000 Series Installation Manual page 81

Table of Contents

Advertisement

Important:
All four fans must be installed at all times to ensure proper ventilation. If a fan fails, replace it as
soon as you can but leave it in place until you do. Leaving a fan bay unpopulated impairs the
ability of the remaining fans to cool the chassis.
Procedure
1. Check the Fan LED on the front of the chassis. Solid green indicates that all fan modules are
operating normally. Blinking amber indicates that a fan module failed.
2. Enter the following command to determine which fan module failed.
show sys-info fan
This command shows the status of each fan module: up, down, or Not Present when a
fan is removed.
3. Remove the fan module that failed by loosening the two thumb screws and pulling the fan
module out of the chassis.
4. Insert the new fan module into the chassis.
Note:
You can hot swap fan modules while the switch is operational.
5. Verify that the fan module is fully seated in the chassis and secure it with two thumb screws.
6. Enter the following command to check the temperature sensors inside the switch.
March 2020
Installing the VSP 8000 Series
Install a Fan Module
81

Hide quick links: