Power Line Voltage Surges; Test Power Line With Multimeter - Graco SaniForce 1040e User Manual

Electric-operated diaphragm pump
Hide thumbs Also See for SaniForce 1040e:
Table of Contents

Advertisement

Troubleshooting the Graco Motor Control
Power Line
Line Voltage
Voltage Surges
Power
Power
Line
Voltage
Power conversion equipment can be sensitive to
voltage fluctuations from the incoming power supply.
The Graco Motor Control is considered to be power
conversion equipment because energy is stored on
a capacitive bus and then modulated to control a
brush-less motor. The design of the Graco Motor
Control takes this into account, and therefore can
withstand a wide range of conditions. However, it
is still possible for supplied power to occasionally
go outside of the tolerable range in industrial plants
with high-amperage reactive pulsed loads, such as
welding equipment.
If the tolerable range is exceeded, an over-voltage
condition is flagged and the system shuts down in
an alarm state for protection and to alert the user of
unstable power. Excessive or repeated over-voltage
events may permanently damage the hardware.
The MAX-HOLD feature on a multimeter can be used
to determine peak DC voltage on the line. DC is the
correct setting, as opposed to AC, because peak
voltage is the critical parameter that affects the DC
voltage level stored on the capacitive bus in power
conversion equipment.
Readings should not regularly exceed approximately
400 Vdc to avoid tripping the 420 Vdc alarm level
in the Graco Motor Control. If the power quality is
suspect, it is recommended to power condition or
isolate the device(s) that is causing the poor power
quality. Consult a qualified electrician if there are any
concerns about the available power supply.
46
Surges
Surges
Test Power
Power Line
Line with
Test
Test
Power
Line
1. Set multimeter to DC voltage.
2. Connect the multimeter probes to the supplied
power line.
3. Press Min Max successively to show the peak
positive and the negative DC voltages.
4. Confirm that readings do not exceed 400 Vdc
(Graco Motor Control alarm is issued at 420 Vdc).
with Multimeter
Multimeter
with
Multimeter
3A3167P

Advertisement

Table of Contents
loading

This manual is also suitable for:

25a87925a88025a88125a882

Table of Contents