Installation

These pumps are positive displacement gear
pumps. The AC motors are 115 VAC, and use
UL and CSA listed TENV motors. The motors
use sealed bearings and require minimal main-
tenance. These pumps are for use with motor
oil, hydraulic fluid, antifreeze, gear lubes and
other oil-based products. The package
includes a bung adapter for mounting on any
standard 2 inch barrel or tank bung.
When unpacking check for shipping damage.
Report any shipping damage to delivering car-
rier immediately. See Parts, page 6.
Mounting Pump on Barrel or
Tank
1. Install bung adapter in 2 in. bung and
tighten.
2. Use a 1 in. (25 mm) steel or PVC pipe with
1 in. npt pipe threads on one end as a suc-
tion tube.
3. Cut tube to a length 1/2 in. (13 mm) less
than the distance from the top of the bung
to the bottom of the tank.
4
4. Apply pipe sealant to threads and install
pipe into pump inlet.
If you are pumping used oil, install suction
tube assembly with inlet suction screen to
filter large contaminants.
If tank depth is greater than 60 in. (1524
mm), an intake check valve may be
required to retain pump prime.
5. Insert the suction tube through the bung
adapter into the tank, and lower the pump
onto the bung adapter.
6. Tighten swivel nut on pump to the thread
on the bung adapter.
7. The pump outlet port is a 3/4 in. npt pipe
port. Make sure hose or pipe used on the
pump discharge is rated greater than the
maximum working pressure rating of the
pump
8. Fill pump outlet with fluid to aid initial prim-
ing.

Mounting Pump In-line

The pump has a 1 in. npt inlet and a 3/4 in. npt
outlet.
If you are pumping used oil, install a suc-
tion screen to filter large contaminates.