2.9.6 Send And Return Module Option Switches
The illustration shows the location of the Send And Return Module internal option switches and defines
their functions.
NOTE: These option switches are also present on the Monaural Output/Telco Mix/Send And Return
Module (PR&E #99-266).
Two-station switch S1 sets whether the Send-1 local and/or remote ON/OFF buttons are momentary
or maintained-action. When momentary-action is selected for the local and/or remote ON/OFF buttons,
Send-1 is active only as long as the button is held depressed.
Two-station switch S2 sets whether the Send-2 local and/or remote ON/OFF buttons are momentary
or maintained-action. When momentary-action is selected for the local and/or remote ON/OFF buttons,
Send-1 is active only as long as the button is held depressed.
The momentary-action function may be desired when using Sends for special effects applications.
PACIFIC RESEARCH & ENGINEERING
S1, Logic Assignment Selector
#
Control
1
Remote
2
Local
1
C1
2
1
C1
2
S2, Logic Assignment Selector
C2
C2
#
Control
1
Remote
2
Local
48
BMX SERIES III CONSOLE
Function
UP: Send-1 ON/OFF button is maintained-action.
DOWN: Send-1 ON/OFF button is momentary-action.
UP: Send-1 ON/OFF button is momentary-action.
DOWN: Send-1 ON/OFF button is maintained-action.
Function
UP: Send-2 ON/OFF button is maintained-action.
DOWN: Send-2 ON/OFF button is momentary-aciton.
UP: Send-2 ON/OFF button is momentary-action.
DOWN: Send-2 ON/OFF button is maintained-action.
REVISION C