Pda Does Not Communicate With Control - ALLIANCE BD3NGBGS303EW01 Original Instructions Manual

Commercial dryer
Table of Contents

Advertisement

Electronic Control Troubleshooting

PDA Does Not Communicate With Control

Attempt to communicate with the electronic control using the PDA.
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
Is there
No
acknowledgement from
the control?
Yes
Check PDA set-up: Com
Yes
port, Baud Rate,
Consumer IR Bit
No
Does the electronic
-C-
control display EI0F
or -C-?
EI0F
Has IR communication
Yes
been turned off?
No
Change electronic
control and repeat
procedure.
38
Check PDA manual for
correct use of IR. Is
there any control
response?
No
Make sure that SDIO
IrDA card is
installed if
required on PDA.
Yes
If PDA displays
control mismatch,
select proper control
type.
Communication
sequence checks out
properly.
Turn IR communication
on (refer to
programming manual).
Part No. D515519R3