Igniter Glows but Burner Does Not Ignite (Gas Dryer Models)

©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
Did flame sensor fail
Yes
in closed position?
No
Is secondary coil or
Yes
holding coil open?
No
Is gas supply
Yes
insufficient?
No
Are igniter and
bracket improperly
Yes
installed on burner
tube assembly?
No
Is sensor improperly
Yes
installed on burner
housing?
25
Replace sensor.
Replace gas valve
coils. Refer to Dryer
Test Procedures
section
Check gas supply and
pressure. Make sure
gas shutoff valve is
turned on.
Loosen screw and
properly position
igniter and bracket
on burner tube
assembly.
Loosen screw and
properly position the
sensor on the burner
housing.