4. MOUNTING AND INSTALLATION OF THE TANK

The mounting (4) of the hot water tank, as well as its connection to the
water (5) and electrical network (6) and commissioning must be performed
by a qualifi ed professional according to our instructions and observing the
In case of improper connection and installation, you will lose
all your guarantee and warranty rights!
The tank must be installed and operated in a frost free
environment!
At the installation location, suitable electrical and water supply and sewage
system must be ensured.
We recommend the following solutions for mounting the appliance:
• Horizontal levelled fl oor to ensure the absolute vertical position of the
appliance. Vertical adjustment can be achieved by appropriately adjusting
the three legs of the appliance.
• The appliance must be installed in such way that a clearance of min. 50 mm
must be left from the wall and at least 700 mm gap must be ensured
between the electrical safety cover and the wall or any other building
structural component, to allow removal of the service cover and cleaning the
inside of the container.
• To decrease heat loss attributable to the hot water pipe, the appliance
should be installed the closest possible to the hot water withdrawal locations.
For larger distances, the hot water pipe must be provided with thermal
insulation.
standards IEC 60364 / MSZ HD 60364.