Automatic Release; Function Test Of The Rotation Break - probst SG-80-PGL2 Operating Instructions Manual

Scissor grab sg
Hide thumbs Also See for SG-80-PGL2:
Table of Contents

Advertisement

Available languages

Available languages

Operation
6.4.2

Automatic release

The automatic release with switching delay avoid a accidently unhocking of the automatic release and
therefore a closing of the device (SG) without a gripping good. Reason for a accidently closing is a jumping
motion of the device (SG), caused when driving very fast over uneven ground with the lifting machine
(excavator).
The fast driving with the device (with or without load) over uneven grounds is forbidden
6.4.3

Function test of the rotation break

Basic position of the rotation
break (before the function test).
As soon as the return in basic position takes less than 2 seconds, the rotation break at the automatic release
must be exchanged unconditional!!! Otherwise exists danger of accidents, because this is a safety part!
5310.0380
Automatic release with
switching delay
Rotation break
(4011.0228)
Ill. F
Raise the automatic release
with one finger and then let it
go.
≥ 2 sec.
Ill. G
Should the return in basic position
takes about 2 seconds, the rotation
break is fully functional.
V10
23 / 26
Ill. E
Ill. H
GB

Advertisement

Chapters

Table of Contents
loading

Table of Contents