2.11 o: Keypad-Related Settings
Note:
Sets the number of the U monitor you will log.
For example, to show U1-03 [Output Current], set o5-05 = 103. When it is not necessary to set data log monitors, set this parameter to 000.
You cannot select U2 monitor [Fault Trace] or U3 Monitor [Fault History].
o5-06: Log Monitor Data 4
No.
Name
(Hex.)
o5-06
Log Monitor Data 4
(1556)
RUN
Note:
Sets the number of the U monitor you will log.
For example, to show U1-07 [DC Bus Voltage], set o5-06 = 107. When it is not necessary to set data log monitors, set this parameter to 000.
You cannot select U2 monitor [Fault Trace] or U3 Monitor [Fault History].
o5-07: Log Monitor Data 5
No.
Name
(Hex.)
o5-07
Log Monitor Data 5
(1557)
RUN
Note:
Sets the number of the U monitor you will log.
For example, to show U1-08 [Output Power], set o5-07 = 108. When it is not necessary to set data log monitors, set this parameter to 000.
You cannot select U2 monitor [Fault Trace] or U3 Monitor [Fault History].
o5-08: Log Monitor Data 6
No.
Name
(Hex.)
o5-08
Log Monitor Data 6
(1558)
RUN
Note:
Set the U monitor number you want to log.
For example, to display U1-01 [Frequency Reference], set o5-08 = 101. When it is not necessary to set a data log monitor, set this parameter
to 000. You cannot set U2 Monitors [Fault Trace] or U3 Monitors [Fault History].
o5-09: Log Monitor Data 7
No.
Name
(Hex.)
o5-09
Log Monitor Data 7
(1559)
RUN
Note:
Set the U monitor number you will log.
For example, to show U1-01 [Frequency Reference], set o5-09 = 101. When it is not necessary to set data log monitor, set this parameter to
000.
o5-10: Log Monitor Data 8
No.
Name
(Hex.)
o5-10
Log Monitor Data 8
(155A)
RUN
446
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Description
Description
Description
Description
Description
YASKAWA TOEPYAIGA5002A GA500 Programming
Default
(Range)
107
(000, 101 - 999)
Default
(Range)
108
(000, 101 - 999)
Default
(Setting Range)
V/f, OLV/PM : 000, OLV,
AOLV/PM, EZOLV : 105
(000, 101 - 999)
Default
(Range)
110
(000, 101 - 999)
Default
(Range)
112
(000, 101 - 999)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga50u series

Table of Contents