V-Sub Adjustment - Sony Power HAD FX HSC300R Service Manual

Hd color camera
Table of Contents

Advertisement

Adjustment Procedure
1.
Open the SERVICE menu, and adjust the item so that the specification is satisfied.
MENU: SERVICE
PAGE: OHB_ADJ1
ITEM: GAIN_CONT [R], [G], [B]
Specification: A = 700 mV
A
A
R
2.
Execute file storing.
MENU: SERVICE
PAGE: OHB_ADJ1
ITEM: STORE FILE
3.
Open the SERVICE menu, and adjust the item so that the specification is satisfied.
MENU: SERVICE
PAGE: WHITE SHADING
ITEM: WHITE [R], [G], [B]
Specification: A = 700 mV
A
A
R
4.
Execute file storing.
MENU: SERVICE
PAGE: WHITE SHADING
ITEM: STORE FILE
5.
Set the value to the value adjusted in steps 1 and 3, and execute file storing for each format.
3-3-4.

V-SUB Adjustment

Preparation
• Setting for MSU-1000
MASTER GAIN → 0
DETAIL OFF button → OFF (lit)
AUTO KNEE button → OFF (lit)
MATRIX OFF button → OFF (lit)
GAMMA OFF button → OFF (lit)
ON button (shutter control block) → OFF (dark)
• Filter position
ND filter → 1 (CLEAR)
• Shoot the grayscale chart so that the chart frame is aligned with the under scanned monitor frame.
• Lens iris: Released
HSC300RF/HSC100RF/HSC300R/HSC100R
100%
A
G
B
100%
A
G
B
3-11