White Clip Level Adjustment - Sony Power HAD FX HSC300R Service Manual

Hd color camera
Table of Contents

Advertisement

4.
Adjust the levels A to desired level for R, G and B respectively.
To adjust all levels for R, G and B simultaneously, adjust them using Master.
(Reference value: A = 686 mV (98% of factory setting))
5.
Operate the menu of MSU-1000.
Touch panel operation: (Page 1) → [Knee] → [Knee Slope]
6.
Adjust the levels B to desired level for R, G and B respectively.
To adjust all levels for R, G and B simultaneously, adjust them using Master.
(Reference value: B = 735 mV (factory setting))
Setting after Adjustment
• Setting for MSU-1000
MASTER GAIN → 0
TEST 1 button → OFF (dark)
KNEE OFF button → OFF (lit)
3-4-11.

White Clip Level Adjustment

Equipment: Waveform monitor (R, G, B)
Test Point: SDI connector
Preparation
• Setting for MSU-1000
MASTER GAIN → 12
TEST 1 button → ON (lit)
HSC300RF/HSC100RF/HSC300R/HSC100R
A
B
3-24