2.
Make a line selection at the center white portion of the grayscale chart.
3.
Operate the menu of MSU-1000.
1)
PAINT button → ON (lit)
2)
Touch panel operation: (Page 1) → [Detail] → [3/3]
4.
Adjust the W Limiter so that the edge at portion B to the desired clip level.
5.
Operate the menu of MSU-1000.
1)
PAINT button → ON (lit)
2)
Touch panel operation: (Page 1) → [Detail] → [3/3]
6.
Adjust the B Limiter so that the edge at portion C to the desired clip level.
3-4-6.
Auto-iris Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI connector
Object: Grayscale chart
Preparation
• Setting for MSU-1000
AUTO IRIS button → ON (lit)
KNEE OFF button → OFF (lit)
• Shoot the grayscale chart so that the chart frame is aligned with the under scanned monitor frame.
HSC300RF/HSC100RF/HSC300R/HSC100R
Line selection
B
C
3-20