3-7-3.
Auto
Iris
Adjustment
Object:
Grayscale
chart
Equipment:
Waveform
monitor
To be extended:
AT-53
board
Preparation:
Set
the
BARS
WB
switch
on
the
side
of
the
camera
to 3200°K.
Set
the
iris
control
to AUTO.
Rotate
@RV2
(IRIS
MODE)/AT-53
board
fully
clockwise
().
Adjustment:
l.
Adjust
the
zoom
control
so
that
the
gray-
scale
chart
frame
touches
the
underscanned
picture
frame
on
the
monitor.
UUTTATTIT
at
Jc
Monitor
Screen
2.
Adjust QRV3
(IRIS
SET)/AT-53
board
so
that
the white
peak
level
"A"
is 700+15mv.
3.
Adjust @RV2
(IRIS MODE)/AT-53
board
so that
the white
peak
level
"A"
is
760+15mv.
4.
Adjust @RV3
(IRIS
SET)/AT-53
board
so
that
the white
peak
level
"A"
is
700+15mv.
DXC-325P (EK)
3-25
AT-53
Board