Available languages

For a correct execution of the programs, set very carefully the data of Menu 01. Selecting oFF
instead of the starting or extinction hour, the stove exclude the automatic starting or extinction
Radiocontrol Display
PROGRAM WEEK-END
M-2-4
CRONO WEEK-END
M-2-4-01
Activate(on) / Deactivate(off) to make operative or to exclude the programmations of the week
START 1 WEEK-END
M-2-4-02
STOP 1 WEEK-END
M-2-4-03
START 2 WEEK-END
M-2-4-04
STOP 2 WEEK-END
M-2-4-05
The program hours will be repeated every day of the week in the same way. For a correct
execution of the programs, set very carefully the data of Menu 01.
Selecting oFF instead of the starting or extinction hour, the stove exclude the automatic starting or
extinction
Menu 03 SELECT LANGUAGE - (setting up the language of the radiocontrol).
Radiocontrol Display
SELECT
LANGUAGE
Available languages : ITALIAN, ENGLISH, DEUTSCH, FRANCAIS
Menu 04 SELECT FEELER (selecting room feeler).
Radiocontrol Display
Select feeler
REMOTECONTROL, The temperature will be taken from the radiocontrol.
INTERNAL, The temperature will be taken from the feeler put on the back of the appliance.
Menu 05 STATUS STAND-BY - (Set up way of appliance extinction according to the room
and boiler temperatures).
Radiocontrol Display
STATUS STAND-BY
ON, If the appliance is exceeding 2°C the set value of room or boiler temperature, it starts the
OFF, If the appliance is exceeding the set value of room or boiler temperature, it will continue to work
Menu 06 STATUS BUZZER - (Setting up of buzzer sound).
Radiocontrol Display
STATUS BUZZER
Available selections: OFF, ONLY ALARMS, ALWAYS ON
OFF – Always off
ON ALWAYS, sound in case of alarm and at any tuch of the buttons of the radiocontrol.
Menu 07 LOAD INITIAL - (Continuos fuel load setting).
Radiocontrol Display
LOAD INITIAL
this operation can only be effected when the appliance on the display is evidencing "OFF". This menu is
utilized to fill the screw feeder when the appliance is new or in case of emptying of the pellet container.
Activate(on)/ Disactivate(off)
the week-end
chronothermostat
Insert 1 starting hour
Insert 1 extinction hour
Insert 2 starting hour
Insert 2 extinction hour
Description
Set up the language of the radiocontrol
Select which room temperature feeler you want to utilize
Available selections : REMOTECONTROL, INTERNAL
Activate(on) / Disactivate(off) the stop modality if the set room
or boiler temperatures have been exceeded .
Available selections : on, oFF
extinction cycle.
at min. power, without extinctinguishing.
Select the buzzer modality you wish
ONLY ALARMS – Sounds only if an alarm has occurred.
Activates the continuos load of fuel
IT IT IT IT- - - - GB
Descriptio
Description
Description
Description
Description
68/120
GB- - - - FR
FR mod. Serie 698TP....
GB
GB
FR
FR
Example
Range
on
on-oFF
07:00
00:00-off
12:00
00:00-off
14:00
00:00-off
off
00:00-off