Lincar Annarita 698 TP Using Instructions And Maintenance page 59

Residential space heating appliances with boiler fired by wood pellets
Table of Contents

Advertisement

Available languages

Available languages

REGULATION of the Power of the appliance.
The appliance has the possibility to be regulated within a range of 5 power levels (1-min, 5-
max), during the first working hours we suggest to put the power regulation on level 3.
The appliance will use the selected power value as maximum value for the function of heating
of the plant, in this way it is possible to restrict the max. power of the appliance.
In any case if the selected power permits to the boiler temperature to reach the selected value,
the appliance will automatically reduce the power (modulation) in order to reduce the
consumption of the fuel.
- By mean of the radiocontrol, out of any menu press on button 5
- Regulate the power of the appliance utilizing the buttons 1 e 2
-Terminate the regulation of the power pressing shortly on button 5, the
modification will be confirmed and the radiocontrol returns to the previous
indication
SELECTION of Room temp. feeler.
It is possible to select in which way you want to take the room temperature. It is possible to
take the temperature by mean of the feeler put on the back of the appliance or by mean of the
feeler put on the radiocontrol. In case you select to use the feeler put on the radiocontrol, pay
attention to the place where it is put.
- By mean of the radiocontrol, out of any menu press on button 7
- Press on button 5 until you reach MENU 04
- Press on button 7 (menu) to enter into MENU04
- With button 1 and 2 select the type of room feeler
(REMCONTR/INTERNAL)
- Terminate the selection pressing shortly twice on
button 3
If you intend to use the feeler on the radiocontrol, we suggest to fix the support of the
radiocontrol in the coolest place of the room. Alternatively, on the lh side of the appliance
there are 2 holes for the fixing of the support.
REGULATION of the Room Temperature
The setting of the room temperature means to put a limit to the heating process of the
appliance, whenever the room temperature exceeds the selected value (i.e. 20°C) the
appliance reduces automatically the power commuting on minimum (power 1)
- By mean of the radiocontrol, out of any menu press on button 4
- Regulate the desired temperature utilizing the buttons 1 e 2
- Terminate the regulation of the room temperature pressing shortly on
button 4, the modification will be confirmed and the radiocontrol returns to
the previous indication.
IT IT IT IT- - - - GB
59/120
GB- - - - FR
FR mod. Serie 698TP....
GB
GB
FR
FR

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Annarita 698 tp-saAnnarita 698 tpvtAnnarita 698 tp-savtAnnarita 698 tpvt steelAnnarita 698 tp-savt steel

Table of Contents