Electrical Connection - Bonnet Neve FLASH User Instructions

Hide thumbs Also See for FLASH:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 25
ENGLISH
1. DESCRIPTION
FLASH, RUSH and CAPTUR are available, in a LT/MT switchable version (for low and medium temperature). The
cabinet is fitted with glass sliders on the top, but there is also an option for MT operation that does not need sli-
ders. RUSH is only available in the MT (medium temperature) version; it can be ordered with and without sliders.
The cabinets are available in two different lengths: 1500 and 2000 mm. Their main features and dimensions are
clearly illustrated in drawings 1 and 2 on pages 12 to 15. As for their weights, empty and packing included, see
table I on page 16. A wide range of optional accessories is also available for enhanced functions. To this respect,
contact the authorised after-sales service only.
2. TRANSPORTATION
The cabinet is contained in a specific package including a pallet that enables transportation by the use of fork lift
trucks. Handle the machine on its own pallet or on a similar platform; use a fork lift truck, either manual or elec-
tric, provided it is adequate for handling such appliances and it has the requisite lifting capacity (see page 16 -
figs. 3 and 4 and table I). Handling is reserved for the authorised after-sales service.
3. DELIVERY AND STORAGE
Prior to accepting the case from the carrier, check the conditions of the package. If it is showing visible damage,
the machine too may have suffered some consequences. If so, unpack the machine in the presence of the carrier
and sign, with reservation, the delivery bill. The manufacturer disclaims all liability for damage caused by tran-
sportation or incorrect handling during storage. Unpacking is reserved for the authorised after-sales service.
Storing temperature must be between -25°C and +55°C, air humidity between 30% and 95%. Keep the case away
from direct sunlight and from the elements.
4. INSTALLATION AND AMBIENT CONDITIONS
The cabinet must not be installed in premises containing explosive gas substances. It can neither be used in the
open nor exposed to the rain.
Prior to connecting the cabinet, make sure that the rating plate data correspond to the characteristics of the exi-
sting electrical system (see page 17 - fig. 8 tab. III). For correct operation, the machine must be placed on a level
floor (see page 16 - fig. 5), far from sources of heat and/or direct sunlight, doors, windows, fans or ventilation
outlets (see page 16 - fig.6). It must be granted a reasonable free front area for customer service.
The room where the appliance is installed must comply with the requirements set forth on page 16, fig. 7 and tab.
II.

5. ELECTRICAL CONNECTION

IMPORTANT: AHEAD OF THE CABINET THERE MUST BE A MULTIPOLAR CIRCUIT BREAKER WITH CONTACTS SPA-
CING AT LEAST 3 MM AND WITH THE ADEQUATE CIRCUIT-BREAKING POWER (SEE FIG. 17, PAGE 19). The posi-
tion of the cutoff switch must enable its actuation in any emergency situation (maximum distance 3 m). Show the
position of the cutoff switch to any prospective operator.
The cabinet must be installed by professionally qualified personnel, in accordance with the instructions provided by
the manufacturer and with local regulations. Incorrect installation may result in damage to people, animals and
property. The manufacturer cannot be held liable for such damage. The cabinet is supplied as including 2m long
cords and the appropriate plugs. Do not exceed this length when connecting to the wall power outlet (see fig. 9 on
page 17).
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flash xlRushCaptur

Table of Contents