SerialNumber
Displays the serial number of the unit. The serial number is a 13
character field. The first seven alphanumeric characters are an
abbreviation representing the product name. The remaining six
digits are the individual unit's number.
get SerialNumber
SerialPortBaudRate
Configures the baud rate for the unit's RS-232 serial port. The
number of data bits per character is fixed at 8 with no parity.
Default: 115200
set SerialPortBaudRate [9600 | 19200 | 38400 | 57600 |
115200]
SaveConfiguration Restart command required
get SerialPortBaudRate
SerialPortEcho
Controls if the unit echoes characters on its RS-232 port. When
enabled, all non-control character keyboard input is output to
the display.
Default: enabled
set SerialPortEcho [enabled | disabled]
get SerialPortEcho
SES
SC 5700
Enables support for SES enclosures that have been discovered
by the appliance.
Default: enabled
set SES [enabled | disabled]
get SES
SESAlarmTest
SC 5700
Turns on the specified enclosure's audible alarm at the specified
warning level. Reset turns off the alarm.
Note
The SESEnclosures command must be
executed before executing
SESAlarmTest [EnclosureIndex] [SET | RESET] [INFO |
NON-CRIT | CRIT | UNRECOV]
SESDiskFailureAlarm
SC 5700
Activates an audible alarm when the appliance determines that
a RAID member disk drive has failed. The enclosure which
contains the failed disk drive creates the sound, other
enclosures are unaffected.
Default: disabled
set SESDiskFailureAlarm [enabled | disabled]
get SESDiskFailureAlarm
xvi
ATTO Technology Inc. FastStream SC Installation and Operation Manual
SESEnclosures
SC 5700
List SES-enabled enclosures which have been discovered by
the appliance.
SESEnclosures
SESIdentify
SC 5700
Tells the appropriate SES enclosure to identify the specified
element(s). ALL identifies all disks. RAID GroupName identifies
all disks in a RAID Group. If the MemberIndex is also specified,
only that disk is identified. ENC and enclosure index identifies
all slots in the specified enclosure. DRIVE BlockDevID identifies
the specified disk.
Note
The SESEnclosures command must be
executed before executing the SESIdentify
ENC or SESIdentify ALL command.
set SESIdentify [ALL | RAID GroupName
<MemberIndex> | ENC EnclosureIndex | DRIVE
BlockDevID]
get SESIdentify [ALL | RAID GroupName
<MemberIndex> | ENC EnclosureIndex | DRIVE
BlockDevID]
SESIdentifyStop
SC 5700
Tells the appropriate SES enclosure(s) to stop identifying the
specified element(s). If the MemberIndex is specified, only that
disk is identified. DRIVE and BlockDevID identify the specified
disk.
SESIdentifyStop [ALL |GroupName <MemberIndex> |
DRIVE BlockDevID]
SESMute
SC 5700
Causes the audible alarms for all known enclosures to be muted
or to use the remind state. The remind state causes an
occasional audible reminder, if supported by the hardware, of
the alarm condition.
Note
The command SESEnclosures must be
executed before executing SESMute.
Default: Mute
SESMute <EnclosureIndex> <remind>